Welcome to the Firelite ANN-80 User Manual. This guide provides comprehensive instructions for installing, operating, and maintaining the ANN-80 Remote Fire Annunciators. Designed for system installers, operators, and maintainers, this manual ensures safe and effective use of the device. Thank you for choosing Firelite.

1.1 Overview of the ANN-80 Series

The Firelite ANN-80 Series consists of compact, backlit LCD remote fire annunciators designed for use with compatible Fire Alarm Control Panels (FACPs). These devices, including the ANN-80, ANN-80-W, and ANN-80C, mimic the FACP display, providing real-time system point status. They are capable of displaying English-language text, including device types, independent point alarms, trouble conditions, and supervisory zones. The series offers customizable alpha labels, enhancing clarity for users. With their sleek design and compatibility with FACPs, the ANN-80 Series is ideal for installations requiring remote monitoring of fire alarm systems. These annunciators are designed to meet industry standards, ensuring reliability and effectiveness in various applications.

1.2 Importance of the User Manual

The Firelite ANN-80 User Manual is essential for ensuring the safe and proper installation, operation, and maintenance of the ANN-80 Series Remote Fire Annunciators. It provides detailed instructions, technical specifications, and troubleshooting guidance, enabling users to maximize the device’s functionality. By following the manual, installers and operators can ensure compliance with industry standards and avoid potential risks associated with incorrect setup. The manual also serves as a reference for understanding system indicators, customizing settings, and performing regular maintenance. Adhering to the guidelines in this manual ensures optimal performance, reliability, and compliance with fire safety regulations. It is a critical resource for anyone working with the ANN-80 Series.

1.3 Target Audience

This manual is designed for professionals involved in the installation, operation, and maintenance of the Firelite ANN-80 Series Remote Fire Annunciators. It is primarily intended for fire alarm technicians, system installers, and facility managers responsible for ensuring fire safety systems are functioning correctly. The manual is also a valuable resource for maintenance personnel and operators who need to understand the device’s operation and troubleshooting procedures. Additionally, it serves as a reference for compliance with industry standards and regulations. By following this manual, users can ensure the ANN-80 Series operates efficiently and meets all safety requirements. It is an essential tool for anyone working with fire alarm systems.

Features and Benefits of the ANN-80 Series

The ANN-80 Series offers a compact, backlit LCD display, English-language text, and customizable alpha labels. It is compatible with FACPs, ensuring reliable fire alarm monitoring and control.

2.1 Compact Backlit LCD Display

The ANN-80 Series features a compact, backlit LCD display designed for clear visibility in various lighting conditions. With an 80-character display ( x 4 lines), it provides detailed system point information. The backlit feature ensures readability in low-light environments, making it ideal for 24/7 monitoring. This compact design allows for easy installation in confined spaces while maintaining full functionality. The display mimics the host FACP, offering a consistent user experience. Its sleek construction and reliable performance make it a robust solution for fire alarm systems. This feature enhances overall system monitoring and control, ensuring critical information is always accessible. The ANN-80’s display is a key component in its ability to deliver accurate and timely alerts.

2.2 English-Language Text Display

The ANN-80 Series features an English-language text display, providing clear and understandable system point information. This includes device type, independent point alarms, trouble conditions, and supervisory zones. The English-language capability ensures that users can quickly interpret critical alerts without confusion. The display mimics the host FACP, offering a user-friendly experience. Custom alpha labels, programmed into the FACP, are also shown, enhancing readability. This feature is essential for facilities requiring clear communication of fire alarm status. The English-language text display is a key advantage, making the ANN-80 Series accessible to a broad range of users. It ensures that critical information is conveyed accurately and promptly, aiding in efficient response to alarms and system events.

2.3 Customizable Alpha Labels

The ANN-80 Series supports customizable alpha labels, allowing users to assign meaningful text to system points. This feature enhances clarity, making it easier to identify specific zones or devices during alarms or troubles. Custom labels are programmed through the FACP and displayed on the ANN-80’s LCD, ensuring consistency across the system. This capability is particularly useful for complex systems with multiple zones or unique naming conventions. By providing clear, descriptive labels, the ANN-80 improves system management and response efficiency. Customizable alpha labels are a key benefit, offering flexibility and precision for tailored system monitoring and control.

2.4 Compatibility with FACPs

The ANN-80 Series is designed to work seamlessly with compatible Fire Alarm Control Panels (FACPs), ensuring reliable communication and system integration. It supports key FACP functions, such as system point status, device type identification, and zone-specific alerts. The ANN-80’s compatibility with FACPs allows it to display real-time updates, mirroring the host panel’s information for consistent monitoring. This integration simplifies system management and ensures accurate information dissemination. The ANN-80 Series is compatible with Fire-Lite’s addressable systems, making it a versatile solution for fire alarm setups. Its design ensures compatibility across various FACP models, providing a reliable and efficient monitoring experience. This feature enhances system performance and user confidence in fire safety operations.

Installation and Setup of the ANN-80 Series

This section guides you through the installation and setup of the ANN-80 Series, including mounting, wiring, and configuration. Proper installation ensures optimal performance and compliance.

3.1 Pre-Installation Requirements

Before installing the Firelite ANN-80 Series, ensure compatibility with your Fire Alarm Control Panel (FACP). Refer to the FACP manual for specific system requirements and wiring guidelines. Verify the power supply matches the ANN-80’s specifications. Ensure the installation location meets environmental conditions, such as temperature and humidity ranges. Properly plan the wiring route, considering wire gauge and distance limitations. The ANN-80 cover must remain attached during mounting to maintain compliance. Familiarize yourself with local fire safety regulations and installation standards. Gather all necessary tools and accessories, such as mounting hardware and wiring materials. Ensure the annunciator is configured for your system’s specific needs before proceeding.

3.2 Step-by-Step Installation Guide

Begin by powering down the Fire Alarm Control Panel (FACP) and ensuring the system is safe for installation. Mount the ANN-80 annunciator in a secure location, ensuring compliance with local fire safety codes. Use the provided mounting hardware to attach the backplate to the electrical box or wall; Carefully route the wires through the backplate’s wire channel, avoiding any damage or kinks. Connect the wires to the appropriate terminals on the ANN-80 and the FACP, referencing the wiring diagram in this manual. Once connected, power up the FACP and test the ANN-80 to ensure proper communication and display functionality. Follow all safety precautions and consult the FACP manual for additional guidance.

3.3 Wiring and Connectivity

Connect the ANN-80 to the Fire Alarm Control Panel (FACP) using the appropriate wiring. Ensure all connections are secure and meet local electrical codes. Refer to the FACP manual for specific wire gauge and distance limitations. Connect the Annunciator’s TB1 terminals to the FACP’s corresponding output terminals. Route wires neatly through the backplate’s wire channel to avoid damage. Power the ANN-80 from the FACP’s auxiliary power output. Verify all connections are correct before powering up the system. Test the Annunciator to ensure proper communication with the FACP. If issues arise, consult the troubleshooting section or contact technical support. Proper wiring ensures reliable operation and system integrity.

3.4 Mounting the Annunciator

Mount the ANN-80 Annunciator on a flat surface using screws suitable for the wall type (e.g., drywall or backbox). Ensure the device is level and securely fastened to prevent movement. The annunciator’s compact design allows for easy installation in various locations. Attach the backplate to the wall or electrical box first, then slide the unit onto the backplate and secure it with the provided screws. Tighten firmly to ensure stability. After mounting, connect the wiring as described in the wiring section. Ensure all connections are secure before powering up the system. The ANN-80 is designed for durability and reliable operation when properly mounted. Follow local electrical codes and manufacturer guidelines for installation. Proper mounting ensures optimal performance and longevity of the device.

Programming and Configuration

Programming the ANN-80 involves navigating the menu system to set custom alpha labels, configure DIP switches, and customize system settings for optimal performance. Follow the on-screen instructions carefully to ensure proper configuration. Refer to the manual for detailed steps and troubleshooting tips. This section provides guidance for advanced users to tailor the device to specific needs. Proper configuration ensures seamless integration with compatible FACPs and reliable operation. Use the provided tools and follow safety protocols when making changes to the system settings. Configuration is critical for ensuring the annunciator functions as intended in a fire alarm system. Always test settings after configuration to verify correctness.

4.1 Navigating the Menu System

Navigating the ANN-80 menu system is straightforward and intuitive. To access the menu, press and hold the Menu button until the display shows the main menu options. Use the Up and Down navigation buttons to scroll through the menu items. Select an option by pressing the Enter button. The menu is divided into main and submenus, allowing you to configure settings such as custom alpha labels, DIP switch configurations, and system preferences. To exit a submenu, press the Back button. The system will automatically save changes when exiting the menu. Always refer to the manual for specific instructions on menu navigation and configuration. Proper navigation ensures accurate setup and optimal performance of the ANN-80 annunciator.

4.2 Setting Custom Alpha Labels

Custom alpha labels on the ANN-80 allow for personalized descriptions of system points, enhancing clarity and functionality. To set custom labels, navigate to the Custom Labels menu using the Up and Down buttons. Select a label location using the Enter button, then use the keypad to input the desired text. Labels can be up to long. Press Save to store your changes. Custom labels are programmed through the FACP, ensuring consistency across the system. Refer to the FACP manual for additional details on label programming. Properly configured labels improve system readability and facilitate quicker responses during events. Always test labels after programming to ensure accuracy and functionality.

4.3 Configuring DIP Switches

Configuring DIP switches on the ANN-80 is essential for proper system operation. Ensure the device is powered off before making any changes. Use a screwdriver to set the DIP switches according to the FACP manual. Each switch corresponds to specific system functions, such as communication protocols or display settings. Incorrect configuration may lead to system malfunctions. After setting the switches, turn the power back on and verify the system operates as expected. For detailed switch configurations, refer to the FACP manual. Always test the system after adjusting DIP switches to ensure proper functionality and compatibility with your fire alarm control panel setup.

Operation and Maintenance

The ANN-80 operates by displaying real-time system status and alarms. Regular maintenance includes cleaning the display and checking connections to ensure reliable performance and system integrity.

5.1 Basic Operations and Controls

The ANN-80 Remote Fire Annunciator operates by mimicking the Fire Alarm Control Panel (FACP) display, showing real-time system status, alarms, andpoint information; Basic controls include the acknowledge button to silence alarms and the reset button to clear them. The LCD display provides clear English-language text, while LEDs indicate system status. Users can navigate through menu options using the front panel buttons. The annunciator also supports customizable settings via DIP switches, allowing tailored configurations. Regular checks ensure proper functionality, and the backlit display adjusts automatically for optimal visibility. This section guides users through daily operations, ensuring seamless interaction with the system.

5.2 Understanding System Indicators

The ANN-80 features visual and textual indicators to monitor system status. LEDs indicate active alarms, troubles, or supervisory conditions, while the LCD displays detailed information. Green LEDs signify normal operation, amber indicates troubles, and red signals alarms. The display shows device types, zones, and custom labels for clear identification. Users can identify system points, such as independent alarms or supervisory conditions, directly on the screen. Understanding these indicators ensures prompt responses to system events. Regular checks of these indicators help maintain system health. For troubleshooting, refer to the FACP manual for detailed wiring and configuration guidance. This section helps users interpret system feedback effectively.

5.3 Troubleshooting Common Issues

The ANN-80 Series may encounter issues such as blank displays, incorrect text, or loss of communication. First, verify all wiring connections and ensure proper DIP switch settings. Check the power supply and confirm the FACP is functioning correctly. For display issues, ensure the backlight is enabled and brightness is adjusted. If problems persist, reset the device or refer to the FACP manual for additional guidance. Regularly inspect wiring for damage or corrosion. If the system indicates trouble, review the trouble log for specific fault codes. Consult the troubleshooting section in the FACP manual for detailed solutions. Always follow safety protocols when servicing the device;

5.4 Regular Maintenance Tips

Regular maintenance is crucial to ensure the ANN-80 Series operates efficiently. Inspect wiring connections for damage or corrosion and clean the LCD display periodically to maintain visibility. Verify that all DIP switches are correctly configured and that the device is properly mounted. Check the power supply and ensure it meets the specified requirements. Update firmware if necessary to maintain system compatibility. Test the annunciator’s communication with the FACP to ensure proper functionality. Keep the surrounding environment within the recommended temperature and humidity ranges. Finally, review the system logs to identify and address potential issues before they escalate. Regular maintenance ensures reliability and longevity of the ANN-80 Series.

Technical Specifications

The ANN-80 Series features an 80-character backlit LCD display, operating on 24VDC with a power consumption of 100mA. It supports English-language text and custom labels, ensuring compatibility with FACPs. The device is designed for indoor use, with an operating temperature range of 32°F to 120°F (0°C to 49°C) and humidity up to 85% RH. Its compact design allows for flexible installation in various environments, meeting industry standards for fire safety systems.

6.1 Display Specifications

The ANN-80 Series features a compact, backlit LCD display with , arranged in a 20×4 configuration. The display provides clear, English-language text, including device types, zone information, and custom alpha labels. The backlit feature ensures visibility in low-light conditions, with adjustable brightness settings. The LCD mimics the host Fire Alarm Control Panel (FACP) display, offering a consistent user experience. The display updates in real-time, reflecting system point status, alarms, and trouble conditions. Its rugged design ensures long-term reliability, while the compact size allows for easy installation in various environments. The display operates within a temperature range of 32°F to 120°F (0°C to 49°C) and humidity levels up to 85% RH, meeting industry standards for fire safety systems.

6.2 Power Requirements

The ANN-80 Series requires a 24 VDC power supply, with a maximum current draw of 150 mA. Power is typically supplied by the connected Fire Alarm Control Panel (FACP). Ensure the power source meets these specifications to maintain optimal performance. The annunciator is designed to operate within a voltage range of 20.5 to 27.6 VDC. Proper wiring is essential, using 18 AWG or larger wires, and should comply with local electrical codes. The device includes over-voltage and short-circuit protection for added reliability. For installations requiring redundant power, an optional external power supply can be connected. Always refer to the FACP manual for specific power requirements and compatibility guidelines.

6.3 Environmental Specifications

The ANN-80 Series is designed to operate in a variety of environmental conditions. The recommended operating temperature range is 32°F to 120°F (0°C to 49°C), with a storage temperature range of -22°F to 140°F (-30°C to 60°C). The device is capable of withstanding relative humidity levels up to 90% non-condensing. For optimal performance, the annunciator should be installed in a clean, dry environment, free from excessive dust or corrosive substances. The NEMA 1-rated enclosure provides basic protection against solid particles and light splashing. Avoid mounting the unit in areas exposed to direct sunlight, high vibrations, or extreme temperature fluctuations. Proper environmental conditions ensure reliable operation and longevity of the device.

Compliance and Certifications

The Firelite ANN-80 Series complies with UL 864 and NFPA 72 standards, ensuring reliability in fire alarm systems. It holds a NEMA 1 rating and is certified for safe use with compatible FACPs.

7.1 Industry Standards Compliance

The Firelite ANN-80 Series is designed to meet rigorous industry standards, ensuring reliability and safety in fire alarm systems. It complies with UL 864, the standard for fire alarm control units, and NFPA 72, which governs the installation and maintenance of fire alarm systems. These certifications ensure the ANN-80 operates effectively in various environments and meets the requirements for fire safety. Additionally, the device adheres to NEMA 1 ratings, indicating its suitability for indoor use and protection against environmental factors. Compliance with these standards guarantees the ANN-80 Series delivers accurate and dependable performance, aligning with the expectations of fire safety professionals and regulatory bodies.

7.2 Relevant Certifications

The Firelite ANN-80 Series holds certifications that underscore its commitment to safety and quality. It is UL 1076 listed for fire alarm and life safety systems, ensuring compliance with rigorous testing standards. Additionally, the ANN-80 meets Environmental Testing Standard UL 50 for enclosures, demonstrating durability in various conditions. The device also carries ETL listings, verifying adherence to safety and performance criteria. These certifications ensure the ANN-80 operates reliably in fire alarm applications, providing users with confidence in its ability to perform under critical conditions. By adhering to these standards, the ANN-80 supports compliant and effective fire safety solutions, making it a trusted choice for professionals.

Resources and Support

Firelite provides comprehensive resources and support for the ANN-80 Series, including detailed manuals, troubleshooting guides, and customer support contact information, available on their official website.

8.1 Accessing Additional Documentation

To access additional documentation for the Firelite ANN-80 Series, visit the official Firelite website. There, you can download product manuals, technical specifications, and troubleshooting guides. For further assistance, explore the resources section, which includes installation guides, user manuals, and compliance certificates. If you need specialized support, refer to the customer support page for contact details and online assistance options. Ensure you have the latest documentation for accurate and safe installation, operation, and maintenance of the ANN-80 Series.

8.2 Customer Support Contact Information

For any inquiries or technical assistance regarding the Firelite ANN-80 Series, contact Firelite customer support. Visit the official Firelite website for comprehensive support resources, including contact forms and regional office information. You can reach Firelite at 203-484-7161 or via email at customer.support@firelite.com. Additionally, fax inquiries can be sent to 203-484-7118. For immediate assistance, refer to the support page on the Firelite website, which provides detailed contact information, troubleshooting guides, and access to expert technical support. Ensure to have your product model and serial number ready for efficient service.